160 psi steam boiler

Seminole 3-Pass Wetback Firetube Boiler | Superior Boiler

Superior Boiler Works Scotch Marine Boilers Available with NOx reduction technology to 9 ppm. With pressures of 15 to 300 psi steam and 30 to 160 psi hot water, the Seminole is the intelligent option for your particular needs. Available in sizes ranging from 70 to 2,500 BoHP.

Apache 2-Pass Dryback Firetube Boiler | Superior Boiler

Superior Boiler Works Scotch Marine Boilers Available with NOx reduction technology to sub 9 ppm. With pressures of 15 to 300 psi steam and 30 to 160 psi hot water, the Apache is the intelligent option for your particular needs. Available in sizes ranging from 40 to 2,500 BoHP.

Superior Boiler – Manley’s Boiler

Pressures from 15-300 psi steam and 30-160 psi hot water; Sizes from 30-1,000 BoHP; Available with NOx reduction technology to sub 9 ppm; Can burn: Natural Gas, Propane, #2 Oil, Digester Gas, Hydrogen; Apache Scotch Marine Firetube Boiler. 2 Pass Dryback Firetube Boiler; Pressures from 15-300 psi steam and 30-160 psi …

INDUSTRIAL BOILERS – P C McKenzie Company

Packaged Firetube, Firebox and Waste Boilers; 4 Pass Wet Back Scotch, Steam and Hot Water up to 250 psig, 100 HP tp 1,500 HP; 3 Pass Wet Back Scotch, 15 to 300 psig Steam,Water 30 to 160 psi; 30 to 1,800 Horsepower; 3 Pass Dry Back, 15 to 300 psig Steam; 30 to 160 …

150 PSI High Pressure Steam Boilers Atmospheric / Natural …

High Pressure Steam Boilers / Atmospheric. 150 PSI Models & Ratings / Natural Gas Fired. Rev. 3/2014. STACK / DRAFT REQUIREMENTS •UL listed for use with Type B Vent. •Minimum stack height including Draft Control is 10 feet. •The stack should be supported independently of the boiler and an adjust-

Fuel & Electric Fuel & Electric Steam Boilers | Precision …

FPS Vertical Firetube Steam Boiler Capacities: 330 PPH to 3,440 PPH (9.5 BHP to 100 BHP) @ up to 83% efficiency Standard Model: ASME Section IV “H” Stamp (15 PSI) or Section I “S” Stamp (150 PSI) Compliances: UL Subject 795/726/2096, ASME Safety …

Steam Boiler: Steam Boiler Classification

A steam boiler in which steam is generated at pressure exceeding 15 psi or a boiler in which hot water is generated at pressure exceeding 160 psi and/or temperature exceeding 250 o …

Boilers | Energy Control Steam and Hot Water Boiler Systems

A steam accumulator is a pressure vessel (or tank) with internals and controls, that can reduce the fuel consumption, maintenance costs and increase the service life of your boiler by stabilizing the steam draw conditions, but it cannot make up for shortcomings …

Difference Between Low- and High-Pressure Boilers | Hunker

High-pressure boilers will heat steam above 15 psi and water at pressures that exceed 160 psig. Temperatures in high-pressure boilers will exceed 250 degrees F. Because of the elevated pressure at which these boilers operate, they need to be monitored to ensure safety at all times.

Used 400 HP 150 psi Steam Boiler – Industrial steam

BEC’s Reconditioned/Used Steam Boiler for Sale or Rent. Brand: Hurst • Hurst Model Number S-2000 150/160W • Power Flame Burner. BEC’s inventory of reconditioned/used industrial boilers are in as good as new condition, All boilers are top name brands like …

UM Group, Inc

6-100 HP, 15-300 psi steam, 30-160 psi hot water The Cyclone Steam Boiler provides for exceptionally high efficiencies, lower fuel costs, and extremely rugged construction. 4VT Cyclone Hot Water 6-100 HP, 15-300 psi steam, 30-160 psi hot water

What is the difference between high and low pressure steam?

Low pressure boilers may be used in steam heating or hot water heating applications. Steam boilers are limited to pressures not exceeding 15 psi. Hot water boilers are limited to pressures not exceeding 160 psi and/or temperatures not exceeding 250° F.

Fuel & Electric Hot Water Boilers | Precision Boilers

PCW Compact Electric Hot Water Boiler Capacities: 50 MBH to 1,500 MBH (1.5 BHP to 44 BHP) @ 99.5% efficiency Standard Model: ASME Section IV “H” Stamp (160 PSI & 250 o F) Compliances: UL Subject 834, NEC/NFPA Article 424-G, ASME Safety Code …

Packaged Boilers | Energy Efficienct Heating | NYC Metro

Our packaged boilers for commercial and industrial use feature: four or three pass water back design; low-pressure steam rated up to 15 psi; hot water rated 30 to 160 psi; 50 to 600 bhp capacity; and 700 to 1,000 bhp capacity for custom builds. Talk to us today.

RTC-160 PSI – Riello

rtc-160 psi High-efficiency 3-pass stainless steel condensing boilers designed both for retrofit and new construction projects. Project costs are reduced thanks to the high water content heat exchanger, that requires no minimum flow rate and eliminates the need of a costly dedicated boiler circulator.

Scotch Marine (Fire Tube ) Boilers | Hurst Boiler

Our two-pass, three-pass or four-pass Scotch Marine(Fire Tube) boilers are available in dryback, wetback, steam or hot water versions; from 15 to 800 hp with pressures to 300 psig. Hurst Scotch Marine boilers are rated to 81% minimum efficiency.

Weil Mclain 160 psi Hydronic Low Water Cut-Off – 511724281 …

15 PSI (Steam), 160 PSI (Water) Complies with CSD-1; Manual reset with test button and indirect light; For use with LGB, 80, 88, and 94 Series boilers; Documents. Warranty. Specifications. Brand Model Compatibility: All Boilers. Maximum Pressure: 160 psi. Origin: Domestic …

RAYPAK RAYTHEM GAS-FIRED BOILER 160 PSI | Steep Hill …

Home / Boilers / RAYPAK RAYTHEM GAS-FIRED BOILER 160 PSI. RAYPAK RAYTHEM GAS-FIRED BOILER 160 PSI. Sold. Make: Raypak: Dimensions (L x W x H) 48" x 40" x 40" Weight: 300kg: Serial Number: 0706267485: … 2013 Columbia High …

Commercial boilers in Maryland, Virginia & DC | Complete …

“D” and “O” style boilers; Field erected boilers; Waste gas heat recovery systems 250 – 1050 psig; Hurst Boiler. Four pass vertical boilers; Three pass 4.5 and 5 square foot firebox boilers; Two pass and three pass wet back or dry back scotch marine boilers; 6 – 1500 horsepower; 15 – 300 psig steam, 30 – 160 psig water; Gas, oil …

PB Heat: Peerless® Boilers – America’s BEST Built Boiler

Consumer Center It all begins with a Peerless ® boiler! Available from your local heating contractor, our boilers are the practical, efficient, clean alternative to furnaces and heat pumps.

How to Set Hot Water or Steam Heating System Pressure …

On a residential heating boiler the automatic water-feeder/pressure reducing valve that automatically provides makeup water to the heating boiler if pressure drops below 12 psi. So 12 psi is the typical "cold" pressure for residential boilers. 12 psi is for typical U.S. …

Kunkle 0537 1×1.25" 160 PSI Section IV Steam Relief Val …

Stock Boilers. WARE’s boiler equipment is from the top manufacturers in the industry for both industrial and commercial applications that’s guaranteed to give you reliable performance and unmatched savings. … Kunkle 0537 1×1.25" 160 PSI Section IV Steam Relief Val Kunkle Steam Relief Valve $315.12 SKU: 0537-E01-HM0160 Qty: Add to Cart. Email …

Bryan “Flexible Water Tube” RW Series Steam & Water Boilers

exceeding 150 psi to maximum of 300 psi design pressure. Hot water boiler Optional construction to ASME Power Boiler Code requirements for tem-peratures exceeding 240° F and/or pressure exceeding 160 psi to maxi-mum of 285° F operating and 300° F design temperature and 250 psi. Bryan RW Series Boilers Standard and Optional Equipment

Boiler Horsepower – Engineering ToolBox

Boiler horsepower – a power unit from the 19 th-20 th centuries – was used to rate the capacity of a boiler to deliver steam to steam engines.. A common definition of one boiler horsepower is the amount of energy required to produce 34.5 pounds (15.65 kg) of steam per hour at pressure and temperature 0 psig (0 bar) and 212 o F (100 o C) – with feed water at pressure 0 psig and temperature 212 o F.

Saturated Steam Temperatures

Temperature of Saturated Steam (not super-heated!) at Various Pressures WARNING: Steam heat is hotter than 212F (boiling water) and increases in temperature as pressure increases.See the steam safety information section.. WARNING: Exposure to steam is hazardous.If not properly controlled, steam can cause property damage, serious bodily injury, or death.

Arizona Boiler Inspection | Boiler inspection in Arizona …

Heating or process boilers not exceeding 15 psi Hot-water boilers not exceeding pressures of 160 psi or not exceeding a temperature of 250 degrees F Lined hot-water heaters exceeding heat input of 200,000 BTU/hour, water temperature of 210 degrees F, and/or nominal water-containing capacity of 120-gallons. Talk to the Experts

Cast-Iron Boilers

ASME BPV Code Section IV service restrictions limit steam boilers to pressures not exceeding 15 psi and hot water boilers to pressures not exceeding 160 psi and/or temperatures not exceeding 250°F. Steam boilers must have at least one safety valve with a set pressure not to exceed 15 psi.

Home – Nationwide Boiler Inc.

Our large selection of inventory – rental boilers, new boilers, refurbished/used boilers, emergency boilers, mobile boiler rooms, and temporary steam plants – will help your operations run as smoothly and efficiently as possible. Nationwide Boiler Inc. pioneered the trailer-mounted rental boiler in 1967.

Coverage of Boiler and Pressure Vessel Laws | www …

Low pressure heating boilers that are not located in a place of public assembly. Water heaters for potable water if the capacity is less than or equal to 50 gallons, the burner input rating is less than or equal to 50,000 Btu, and the maximum allowable working pressure is less than 160 psi.